The Rainwater Harvesting Worksheet calculates how much of a roof’s average annual runoff (and so how much of its nitrogen and phosphorus load) is kept out of the surface discharge when it is stored in a cistern or rain barrel and used on site. Open it from a catchment whose treatment is Rainwater Harvesting. Set the catchment up so that its area is the roof: the worksheet takes its contributing area from the catchment.


Description
Rainwater harvesting refers to water collected from roofs. The water is stored and used for beneficial purposes, usually onsite. The contributing area must be the roof area.
Rain is a source of relatively clean, soft water. As rain falls on non-roof surfaces such as pavement and grass, it contacts more contaminants than it would from a roof. Thus, harvested roof runoff can often be used with minimal treatment.
Harvesting rainwater from roof runoff is a method of disconnecting impervious surfaces and capturing water before it contacts many potential contaminants. Runoff as a fraction of rainfall was calculated for ten different roof surfaces and slopes allowing an estimate of runoff for future use (Wanielista, M.P., Chopra, M., Hardin, M., Kakuturu, S., and Runnenbaum, N. (2011). Evaluating Runoff and Abstraction from Impervious Surfaces as Components Affecting Recharge. University of Central Florida, Orlando Florida).
They calculated abstraction of rain by various materials and slopes, and these values are built into BMPFast as the Roof Factor for each Roof Type (see the table under Inputs).
Source reference
Wanielista, M.P., Chopra, M., Hardin, M., Kakuturu, S. and Runnenbaum, N. (2011). Evaluating Runoff and Abstraction from Impervious Surfaces as Components Affecting Recharge. University of Central Florida: runoff as a fraction of rainfall for ten roof surfaces and slopes; these are the Roof Factors of RainwaterHarvesting.RoofTypes, which turn the roof area into the equivalent impervious area.
One popular use for capturing and reusing roof runoff is replacing potable water. Harvested rainwater is commonly used for:
- Outdoor irrigation
- Car washing
- Toilet flushing
- Clothes washing
- Cooling tower make-up
- Irrigation of indoor planters
- Hose bibs
- Rarely, potable use after treatment
Most indoor uses require approval of the local Health Department or Planning Department.
Types of Rainwater Harvesting Systems in Florida
There are four systems typically used in the State of Florida:
- Small residential systems storing rainwater in rain barrels for supplemental irrigation
- Large residential or commercial systems storing rainwater in cisterns for irrigation, vehicle washing, dust control, or other outdoor non-potable uses
- Large residential or commercial systems storing rainwater in cisterns for indoor graywater uses such as toilet flushing, urinal flushing, HVAC make-up water, laundry wash water and outdoor non-potable uses
- Rare systems for purification of stored rainwater as a potable water source
Rainwater or Stormwater Harvesting?
Rainwater Harvesting and Stormwater Harvesting use the same calculations and the same harvesting efficiency (REV) curves. All the calculations and curves are in inches per day (over the Equivalent Impervious Area). The only difference is where the water is collected from:
- Rainwater Harvesting collects only from rooftops. Use it when all the harvest volume can be used.
- Stormwater Harvesting collects from anywhere in the catchment. Using all the harvest volume is not a requirement. The volume harvested can exceed the maximum available volume, because the water is stored in a wet detention facility, which can have additional sources of water (such as groundwater).
Whether the water is used every day or twice per week is not important: the curves work with the average rate of use per day.
Inputs
Rainwater Harvesting works in square feet throughout: the areas on the worksheet, in its report and on its Equations page are in sf (the catchment tables elsewhere in BMPFast stay in acres).
| Input | Units | What it means / how it is used |
|---|---|---|
| Roof Type: | — | The roof surface and slope, chosen from a fixed list (below). It sets the Roof Factor, the fraction of rainfall that runs off that roof. Equivalent Impervious Area (EIA) = Contributing Area × Roof Factor. A Roof Type must be chosen before Sizing will open, and without one the EIA is not calculated. |
| Contributing Area (SF): | sq ft | Read only (greyed). Filled in from the catchment: its post-development area less any BMP (pond) area, converted to square feet — a retention pond’s area is not harvested from or irrigated over. To change it, change the catchment’s area. It should be the roof area. |
| Harvest Rate (0.1 – 4.0 in/week) | in/week | The average annual rate at which the stored water is used, as inches per week over the irrigation area. Converted to cubic feet per day and then to inches per day over the EIA for the efficiency lookup. The range in the label is the range of the design curves; the form does not stop a value outside it. |
| Available Harvest Volume (gal): | gallons | The storage volume that can be drawn down for use (cistern or barrel size). Converted to inches over the EIA for the efficiency lookup. |
| Area Available for Irrigation (SF): | sq ft | The area the harvested water is applied to. With the Harvest Rate it fixes the daily use. |
Roof Type choices
| Roof Type | Roof Factor |
|---|---|
| ASPHALT, 0.2% SLOPE | 0.4175 |
| ASPHALT, 2.0% SLOPE | 0.5942 |
| CONCRETE, 0.2% SLOPE | 0.9531 |
| CONCRETE, 2.0% SLOPE | 0.9457 |
| SHINGLES, 25% SLOPE | 0.9587 |
| SHINGLES, 5% SLOPE | 0.8371 |
| SHINGLES, 50% SLOPE | 0.9544 |
| TILE ROOF, 25% SLOPE | 0.9678 |
| TILE ROOF, 5% SLOPE | 0.9627 |
| TILE ROOF, 50% SLOPE | 0.9723 |
The rainfall zone, rainfall, curve number, DCIA and the nitrogen and phosphorus loads come from the catchment and project; they are not entered here. The harvesting system draws only on its own catchment’s runoff: flows routed from upstream catchments always bypass it and go on, untreated, to the next catchment (see Routing).
Results
After Calculate, the right-hand pane shows the report:
- Rainwater Harvesting Input Variables — Contributing Area (sf), Total Area Available for Irrigation, Available Harvest Volume (gallons), Available Harvest Rate (in/week), Equivalent Impervious Area (sf), and Harvest Volume (in over EIA).
- Water Budget — in gallons per year: Water Use (the irrigation at the harvest rate), Harvested Water Supply (the roof runoff the harvest captures) and Supplemental Water Needed (Water Use − Harvested Water Supply, or 0 when the harvest covers the use): the irrigation water that must come from another source.
- Watershed Characteristics — Watershed Area, Contributing Area to BMP, Non-DCIA Curve Number, DCIA Percent, Rainfall Zone and Rainfall, from the catchment.
- Surface Water Discharge — Provided Nitrogen and Provided Phosphorus Treatment Efficiency (%). Both equal the Harvest Efficiency.
- Surface Discharge Load Diagram — Load in (N and P, kg/yr; runoff Q, ac-ft/yr), Treatment (N and P %), Surface Discharge (N, P and Q leaving), and Mass Reduction (N and P, kg/yr). The diagram is for this catchment on its own; no routing is done here.
The status strip along the bottom of the window shows the project’s Maximum % Removal for TN and TP, the targets to compare the result against.
Buttons
| Button | What it does |
|---|---|
| Calculate / Equations / Report | When any input has changed since the report was shown, the button reads Calculate: a click reads the boxes, calculates and shows the report. Once the report is current, the button switches the pane between the Equations page and the Report. |
| Opens what the pane is showing (report or Equations page) in the Report Viewer, from where it can be printed. | |
| Back | Reads the boxes, calculates, marks the project as changed and closes the worksheet. |
| Efficiency | Opens the Table Viewer with the harvesting efficiency table for the project’s rainfall zone: Harvest Efficiency (%) rows from 20 to 90, Harvest Volume (in over EIA) columns from 0.25 to 6.0, and the Harvest Rate (in/day over EIA) in the cells. Find boxes look up a row, column or table value; the menu has Print, Plot and Back. |
| Sizing | Opens the Sizing form, where Available Harvest Volume, Area Available for Irrigation (sf) and Available Harvest Rate can be stepped or plotted against the N and P removal targets. Apply keeps the values on the BMP; Cancel discards them. Sizing will not open until a Roof Type is chosen. Past the end of the design curves the plot is dotted: more volume gives no more efficiency there. See Sizing. |
| Cost | Opens the life-cycle Cost Analysis for this BMP (construction, replacement, operation and maintenance, energy, present worth and cost per pound of N and P). |
| Help | Opens this page. |
Equations
Methodology. Harvesting and Greenroof Methodology explains how BMPFast reads the REV curves for a roof and cistern, with a worked example.
These are the equations the program applies (also shown on the Equations page, with the current values):
Equivalent Impervious Area EIA (sf) = Contributing Area (sf) x Roof Factor
Volume over EIA (in) = Harvest Volume (gal) / 7.4805 gal/cf / EIA (sf) x 12
Harvest Rate (cf/day) = Harvest Rate (in/week) x Irrigation Area (sf) / (7 x 12)
Rate over EIA (in/day) = 12 x Harvest Rate (cf/day) / EIA (sf)
Harvest Efficiency (%) = REV table lookup of (Volume over EIA, Rate over EIA)
Water Use (gal/yr) = Harvest Rate (in/week) x 52 / 12 x Irrigation Area (sf) x 7.48052 gal/cf
Harvested Water Supply (gal/yr) = Harvest Efficiency / 100 x EIA (sf) x Annual Rainfall (in) / 12 x 7.48052 gal/cf
Supplemental Water Needed (gal/yr) = Water Use - Harvested Water Supply (never below 0)
- The Roof Factor is set by the selected Roof Type.
- The REV (Rate-Efficiency-Volume) table is the one for the project’s rainfall zone, the same curves used by Stormwater Harvesting. A Volume over EIA beyond the last column of the table (6 in) is treated as 6 in: more storage beyond the curves gives no further efficiency. Each REV curve ends before 6 in (the low-efficiency curves stop between about 1.8 and 5 in); from a curve’s end to 6 in, its final value is used.
- Harvest Efficiency is capped at 90% and is never less than 0. Below 20%, the lowest REV curve, BMPFast extends the line between the 20% and 30% curves, beyond the published curves (Wanielista, 2009); the value is kept, and the report says so in a note under the input table. Treat such a value as an estimate.
- N and P removal are equal to the Harvest Efficiency.
- The Water Budget does not change the removal. Annual Rainfall is the project’s mean annual rainfall.
- The Values table on the Equations page lists Treatment Depth, Non-DCIA Curve Number, DCIA Percent and Treatment Rate, as it does for every retention-type BMP. Rainwater Harvesting does not use them: its efficiency comes from the REV curves of the Rainfall Zone, and its Treatment Depth is always 0. The Equations page says so in its notes.
Applicant’s Handbook reference
Appendix O, Table 1 (BMP Efficiencies), Stormwater harvesting: credit is the annual load “not discharged because used for irrigation”, estimated with “the rate-efficiency-volume [REV] curve methodology used by DEP”; BMPFast reads the REV curves for the rainfall zone and uses the harvest efficiency for both N and P.
Section 2.0 Definitions and Terms, “Stormwater harvesting”: “capturing stormwater for irrigation or other beneficial use”; rainwater (roof) harvesting is this, with the roof as the catchment.
Appendix O, Table 1 (BMP Efficiencies), Stormwater harvesting: names the REV curves (Wanielista et al. 1991; Wanielista and Bradner 1992) and says harvesting is evaluated case by case; BMPFast goes beyond the published curves when it extends the line below the 20 % curve, and the report says so.
Source reference
Harper, G.M. (1991). Design Curves for the Reuse of Stormwater. M.S. thesis, University of Central Florida; the same curves in Wanielista, M.P., Yousef, Y.A., Harper, G.M. and Dansereau, L. (1991), Design Curves for the Reuse of Stormwater (link): long-term simulations of a harvesting pond with historical rainfall give, for each zone, curves of the use rate needed for each harvest efficiency at each storage volume (both over the equivalent impervious area); the simulations assume no net groundwater exchange, rain on the pond equal to evaporation, use twice a week and at most 1 in of drawdown.
Wanielista, M.P. (2009). Review of the REV Curves. Memorandum, May 20, 2009, Stormwater Management Academy, University of Central Florida: fits each REV curve with a fifth-order polynomial, adds curves down to 20 %, drops the 95 % curve, and limits the curves to 0.25 to 6 in of storage (1 to 6 in for the 90 % curve); BMPFast builds its table from these polynomials.
BMPFast method (Harvesting, StormwaterHarvesting and RainwaterHarvesting classes; below 20 % decided by Ron, 2026-10-13): the efficiency is capped at 90 %, the highest curve the memorandum keeps; past a curve’s fit limit its last value is held out to 6 in; storage below 0.25 in is read at 0.25 in; and below the 20 % curve the line between the 20 % and 30 % curves is extended, beyond the published curves.
Sample problems
Worked problems solved in BMPFast, each with every input, the steps with screen captures, the program’s results, a hand check and the project file to download. Captures are for demonstration only. All of them: BMPFast sample problems.