The Composite CN Calculator works out one Non-DCIA curve number for a catchment whose pervious (non-directly-connected) area is a mix of soils, covers or disconnected impervious surfaces. Instead of averaging the curve numbers by area, it weights them by the average annual runoff each part produces, which is what BMPFast needs to compute annual runoff correctly. Use it when the Non-DCIA area of a catchment is not uniform, for example when some impervious area is disconnected and drains onto pervious ground.
Open it with the + button beside Pre-Development Non DCIA Curve Number or Post-Development Non DCIA Curve Number on the Watershed Characteristics Worksheet. Each condition (pre and post) keeps its own list of areas and curve numbers with the catchment.

How to use it
- Set the DCIA percentage for the condition on the worksheet first; the calculator uses it (shown as DCIA Percent).
- In the grid, enter one row per part of the Non-DCIA area: its Area (ac) and its CN. Use CN = 95 for impervious area that is disconnected. Start in the first row; the result is 0 if the first row is empty. Up to 20 rows.
- Press Calculate to see each row’s C and Weighted C and the Composite CN.
- Press Back, then answer Yes to put the Composite CN into the worksheet’s Non DCIA Curve Number box.
Inputs
| Input | Units | What it means / how it is used |
|---|---|---|
| Area (ac) | ac | Area of this part of the Non-DCIA area. The rows should add up to the catchment’s Non-DCIA area (see the area check below). |
| CN | CN | Curve number of this part. Use 95 for disconnected impervious area. Kept with 2 decimals (61.50): Curve Numbers are typically rounded to the nearest integer; 2 decimal places are used here for computational accuracy. Rest the mouse on the column heading to see this note. |
Results
| Result | Units | Meaning |
|---|---|---|
| C (grey column) | 0–1 | Annual runoff coefficient of the row, read from the ROC table for the project’s rainfall zone at the row’s CN and the catchment’s DCIA percentage. |
| Weighted C (grey column) | 0–1 | The row’s C times its share of the total area entered. |
| Avg Weighted C | 0–1 | Sum of the Weighted C column: the area-weighted annual runoff coefficient. |
| DCIA Percent | % | The catchment’s DCIA percentage for this condition (from the worksheet; not editable here). |
| Composite CN | CN | The curve number that gives the Avg Weighted C at this DCIA percentage in the ROC table. Shown only when it is between 30 and 100. |
Method
C_i = ROC table(rainfall zone, CN_i, DCIA %)
Weighted C_i = C_i × A_i / ΣA
Avg Weighted C = Σ Weighted C_i
Composite CN = the CN for which ROC table(rainfall zone, CN, DCIA %) = Avg Weighted C (inverse interpolation)
Because each part is weighted by the runoff it produces, the result lies between a simple average and an area-weighted average of the curve numbers. See the worked example on the Catchment Characteristics page (composite CN 76.12 compared with 81.5 for a simple average and 70.87 for an area-weighted average).
Applicant’s Handbook reference
Section 9.2.1 Calculating Predevelopment and Post-development Hydrology, paragraphs b and c: the ROC of each part comes from Appendix N for the zone at its non-DCIA CN and the catchment’s DCIA, and the handbook asks for a ROC for each land use in a catchment; it gives no composite CN method, so this calculator is BMPFast’s way of turning the parts into one CN that gives the same annual runoff.
Source reference
Harper, H.H. and Baker, D.M. (2007). Evaluation of Current Stormwater Design Criteria within the State of Florida. Final report, FDEP Contract S0108, Appendix C (Calculated Annual Runoff Coefficients for the Designated Meteorological Zones as a Function of Curve Number and DCIA) and Section 4.2.1 (link): the annual runoff coefficient (ROC) tables were made by continuous simulation with the SCS curve number method, runoff from DCIA starting after 0.1 in of rain; BMPFast reads these tables for every catchment, and Appendix N of the handbook reproduces them.
BMPFast method (frmCompositeCN): weighting the parts by runoff and finding the composite CN by inverse interpolation are BMPFast’s; so is CN 95 for disconnected impervious area, where Harper and Baker (2007, Section 4.2.1) use 98.
Buttons
| Button | What it does |
|---|---|
| Calculate | Stores the rows with the catchment and recalculates C, Weighted C, Avg Weighted C and Composite CN. |
| Back | Stores the rows, checks the total area, then asks “Do you want to use this value as the Curve Number?”. Yes writes the Composite CN into the worksheet; No leaves the worksheet’s CN unchanged. The calculator then closes. Its tooltip: “Saves the values to this catchment and returns to Catchment Characteristics (you are asked whether to use the result)”. It was labelled “Use Value and Return” before; the Composite EMC calculator uses the same name. |
| Cancel | Closes without storing the grid. (Rows already stored by Calculate stay with the catchment.) |
| Copy | Copies the grid (headings and every row with an area) to the clipboard as tab-separated text, ready to paste into a spreadsheet. |
| Paste | Pastes tab-separated rows from a spreadsheet into the grid, starting at the first row and the Area column (copy just the Area and CN columns). Press Calculate afterwards. |
| Help | Opens this page. |
Messages
- Area Sum Mismatch – shown by Back when the areas entered differ by more than 0.01 ac from the area the program expects: for post-development, the Non-DCIA area (Total Post-Development area − Wet Pond (BMP) area − DCIA area); for pre-development, the Total Pre-Development area. Answer No to return to the grid and fix the areas, or Yes to continue. No check is made if all areas are 0.
- Invalid Composite CN – the calculated value is outside 30 to 100 (for example the first row is empty); nothing is written to the worksheet, and the composite CN is not shown on the form. Adjust the rows and try again.
Shared data: the Area and CN rows are the same list the Composite EMC calculator uses for that condition. Changing them in one calculator changes them in the other.
Impervious area that is not directly connected: curve number 95 to 98, the designer’s choice (Ron Eaglin, October 19, 2026). Harper and Baker (2007), Section 4.2.1, page 4-28, the source of BMPFast’s runoff tables, use 98; BMPFast’s calculator titles say 95. A higher value gives more runoff and a higher post-development load: say which you used.
Sample problems
Worked problems solved in BMPFast, each with every input, the steps with screen captures, the program’s results, a hand check and the project file to download. Captures are for demonstration only. All of them: BMPFast sample problems.