The Vegetated Natural Buffer Worksheet is where you describe a vegetated natural buffer (VNB) that treats the runoff from one catchment, and see how much nitrogen and phosphorus it removes. Open it from the catchment’s treatment choices when the catchment’s runoff flows as sheet flow through a natural, undisturbed vegetated area before it reaches a receiving water or wetland. Enter the buffer’s dimensions and soil storage, choose how the buffer is credited (Retention or Detention + Plants), and press Calculate.


Description
Vegetated buffers, commonly called Vegetated Natural Buffers (VNBs) to emphasize the need for natural areas (not constructed areas), consist of vegetation suitable for sediment removal, nutrient uptake, and soil stabilization. These areas are set aside between developed areas and a receiving water or wetland for stormwater treatment purposes. They can also be used as a pre-filter for other BMPs.
Under certain conditions, VNBs are an effective best management practice for control of stormwater pollutants in overland flow by providing opportunities for:
- Filtration
- Deposition
- Infiltration
- Absorption
- Adsorption
- Decomposition
- Volatilization
VNBs are most commonly used as an alternative to, or in combination with, swale/berm systems installed between residential or commercial backyards and receiving waters.
Potential impacts to adjacent wetlands and upland natural areas are reduced because fill is not required to establish grades that direct stormwater flow from the back of the lot toward the front for collection in the primary stormwater system.
Additional impacts are potentially reduced since VNB strips can:
- Serve as wildlife corridors
- Reduce noise
- Reduce the potential for siltation into receiving waters
A schematic of a buffer is:

Vegetated natural buffers are not intended to be the primary stormwater management system for residential developments. They are most commonly used to treat rear-lot portions of development that cannot be feasibly routed to the primary system serving roads and lot fronts. Use of a VNB in combination with other BMPs is only allowed if the applicant demonstrates there are no practical alternatives for those portions of the project.
Important:
The contributing area (CA in the figure) must equal the runoff area plus the VNB area: Width of Feeder Area × Buffer Length + Buffer Width × Buffer Length. It must also equal the catchment’s area, entered on 1. Enter Catchment. BMPFast shows the three areas in the report and warns when their sum differs from the catchment’s area by more than 1 %. The warning gives the Width of Feeder Area that makes them equal.
Design guidelines for natural buffers are found in: Bentrup, G. (2008). Conservation Buffers: Design Guidelines for Buffers, Corridors, and Greenways. Gen. Tech. Rep. SRS-109. Asheville, NC: USDA Forest Service, Southern Research Station. 110 p. Link
Buffers are typically not normal geometric shapes, such as squares or rectangles. Convert the VNB area to an equivalent rectangle defined by a width (in the direction of flow) and a length. Feeder areas may direct runoff into the natural area, such as constructed setbacks in residential development; the feeder width is entered separately.
Two ways to credit a buffer
The drop-down at the top of the worksheet decides how BMPFast credits the buffer. Projects saved before this choice existed open as Retention.
- Retention — the buffer soil stores and infiltrates runoff. The buffer width, storage depth, soil storage capacity and feeder width give a Treatment Depth (inches over the area draining to the buffer). The hydraulic capture is read from the retention efficiency curves for that depth, and the nitrogen and phosphorus removal are equal to the hydraulic capture. The buffer tables and the slope are not used.
- Detention + Plants — no volume is retained, so the hydraulic capture is 0. The nitrogen and phosphorus removal are read from the buffer tables below for the buffer width and slope. The Treatment Depth is not used. This removal is credited to the vegetation only, so the Equations page labels it “* with vegetation only”.
Applicant’s Handbook reference
Appendix O, Table 1 (BMP Efficiencies), Green Stormwater Infrastructure Efforts: Vegetated Natural Buffers are listed with “Use appropriate retention or detention calculation for volume captured then add an additional removal based on plant, soil and media selections in a treatment train configuration”; BMPFast offers the two parts as a choice: Retention credits the volume captured only, and Detention + Plants credits the plants only, from buffer tables that are not in the handbook.
Inputs
The labels below are as they appear on the worksheet. The names in brackets are the names used in the report, on the Equations page and in Sizing. The ranges in the labels are guidance: the worksheet does not change a value you type outside them, but see the notes on what happens outside the buffer tables.
| Input | Units | What it means / how it is used |
|---|---|---|
| Retention or Detention + Plants | — | Choose Retention or Detention + Plants (see above). [Retention or Detention + Plants] |
| Buffer Width (10 – 350 ft) | ft | Width of the buffer in the direction of flow. Retention: enters the Treatment Depth equation. Detention + Plants: the width used to read the buffer tables (10 to 350 ft; outside that range the removal is 0). [Buffer Width] |
| Buffer Length (ft) | ft | Length of the buffer across the flow (of the equivalent rectangle). It does not change the removal, but it is part of the buffer’s design: permit applications need it, so it is shown in the report and offered in Sizing. [Buffer Length] |
| Storage depth (<= 1ft) | ft | Depth of buffer soil available to store water, above the seasonal high water table. Retention only: enters the Treatment Depth equation. No more than 1 ft: the worksheet refuses a deeper value when you Calculate, Plot, size or go Back, and says so. [Buffer Depth] |
| Width of Feeder Area (ft) | ft | Width (in the direction of flow) of the area that drains onto the buffer, such as a lawn setback behind the lots. Retention only: the runoff from the buffer plus the feeder area is spread over the buffer, so a wider feeder area lowers the Treatment Depth. [Width of Area Feeding Buffer] |
| Soil Storage Capacity (in/in) | in/in | Water the buffer soil can hold per inch of depth. Retention only: enters the Treatment Depth equation. Example values: sandy soil about 0.4 in/in; Hydrologic Group C and D soils as low as 0.16 in/in. [Water storage capacity of soil] |
| Buffer Width Slope (2-6%) | % | Slope of the buffer in the direction of flow. No more than 6 %: BMPFast limits the slope to 6 %: the buffer tables have data for 2 % and 6 % slopes only, and there is no data for steeper slopes. The worksheet refuses a steeper slope when you Calculate, Plot, size or go Back, and says so. Detention + Plants only: the slope used to read the buffer tables (below 2 % the removal is 0). Not used for Retention. [Slope of Buffer] |
The note “For undisturbed areas” under the inputs and “* Applies only to an undisturbed VNB” at the bottom of the worksheet are reminders that the buffer credit applies only to natural, undisturbed vegetated areas.
The watershed values the calculation also uses (catchment area, non-DCIA curve number, DCIA percent, rainfall zone and rainfall) come from the catchment and the General Site Information; they are not entered here.
Buffer tables (Detention + Plants)
Research for nitrogen removal was conducted by the National Risk Management Research Laboratory and published as Riparian Buffer Width, Vegetative Cover, and Nitrogen Removal Effectiveness: A Review of Current Science and Regulations, EPA/600/R-05/118, October 2005 (Link). Infiltration of runoff water was noted as one way natural areas can reduce discharge mass and water volume. There are two removal mechanisms: lateral seepage flow and overland flow. How the table values come from the report is explained under Source of the buffer tables, below.
BMPFast uses the nitrogen (TN) and phosphorus (TP) removal below. The removal is interpolated linearly in both width and slope. The slope is limited to 6 % (there is no data for steeper slopes); the worksheet refuses anything steeper. A width outside 10 to 350 ft or a slope below 2 % gives a removal of 0, and the Equations page says so.
| Buffer Width (ft) | TN at 2 % slope (%) | TP at 2 % slope (%) | TN at 6 % slope (%) | TP at 6 % slope (%) |
|---|---|---|---|---|
| 10 | 50 | 25 | 10 | 5 |
| 25 | 60 | 40 | 15 | 10 |
| 50 | 65 | 55 | 25 | 15 |
| 100 | 75 | 60 | 45 | 25 |
| 350 | 90 | 65 | 60 | 65 |
Example: a 50 ft wide buffer on a 4 % slope is halfway between the two rows, so the removal is N = (65 + 25) / 2 = 45 % and P = (55 + 15) / 2 = 35 %.
Source of the buffer tables
Nitrogen. The TN values come from Mayer, P.M., Reynolds, S.K. Jr., Canfield, T.J. and McCutchen, M.D. (2005), Riparian Buffer Width, Vegetative Cover, and Nitrogen Removal Effectiveness: A Review of Current Science and Regulations, EPA/600/R-05/118, U.S. EPA National Risk Management Research Laboratory, Ada, Oklahoma (EPA PDF). The report gathers 40 peer-reviewed studies that give 66 pairs of buffer width and nitrogen removal, and fits the equation removal (%) = a × ln(width in metres) + b to them (the report’s Table 2). Two of its fitted equations are used:
- 2 % slope row: all studies, N removal = 10.5 × ln(W) + 40.5. On a gentle slope most runoff soaks in and moves through the buffer as lateral seepage. The report gives 50, 75 and 90 % removal at about 3, 28 and 112 m (10, 92 and 367 ft).
- 6 % slope row: surface (overland) flow, N removal = 20.2 × ln(W) − 21.3. On a steeper slope more runoff crosses the buffer on the surface, where removal is lower. The report gives 50, 75 and 90 % removal at about 34, 118 and 247 m.
W is the buffer width in metres (feet × 0.3048). The equations read at the table’s widths, and the values BMPFast uses:
| Buffer Width (ft) | All studies equation (%) | TN at 2 % slope (%) | Surface flow equation (%) | TN at 6 % slope (%) |
|---|---|---|---|---|
| 10 | 52 | 50 | 1 | 10 |
| 25 | 62 | 60 | 20 | 15 |
| 50 | 69 | 65 | 34 | 25 |
| 100 | 76 | 75 | 48 | 45 |
| 350 | 89 | 90 | 73 | 60 |
The 2 % row is the all-studies equation rounded. The 6 % row follows the surface-flow equation, rounded down, except at 10 ft, where it allows 10 %.
The report covers nitrogen only; it does not analyse phosphorus, TSS or slope. Its findings were also published in a peer-reviewed journal: Mayer, P.M., Reynolds, S.K. Jr., McCutchen, M.D. and Canfield, T.J. (2007), Meta-analysis of nitrogen removal in riparian buffers, Journal of Environmental Quality 36:1172–1180 (DOI).
Phosphorus. The TP values come from the original BMPTrains model, developed at the UCF Stormwater Management Academy, and are carried into BMPFast unchanged. The model is described in the BMP Trains 2020 User Manual, Stormwater Management Academy, University of Central Florida, December 2021 (Link).
Source reference
Mayer, P.M., Reynolds, S.K. Jr., Canfield, T.J. and McCutchen, M.D. (2005). Riparian Buffer Width, Vegetative Cover, and Nitrogen Removal Effectiveness. EPA/600/R-05/118, Table 2 (link): the TN rows are this report’s fitted equations, removal = a × ln(width in m) + b: the 2 % slope row is the all-studies equation rounded, and the 6 % row the surface-flow equation rounded down (10 % at 10 ft).
Wanielista, M.P., Hardin, M. et al. (2021). User Manual for the BMP Trains 2020 Model. Stormwater Management Academy, University of Central Florida, buffer tables (link): the TP rows are the original BMPTrains model’s and are carried into BMPFast unchanged; the study behind them is not given.
BMPFast method (slope limit; Ron, 2026-10-08): the slope is limited to 6 %, because the tables have data for 2 % and 6 % only.
The buffer and filter strip removal calculations and tables were approved for use in BMPTrains, with FDOT and water management district staff involved in their development and use. The Applicant’s Handbook Vol. I, Appendix O, for buffers and filter strips, says to use the retention or detention calculation for the volume captured, then add removal for the plant, soil and media selections as a treatment train. Its data source is Harper, H.H. and Baker, D.M. (2007), Evaluation of Current Stormwater Design Criteria within the State of Florida, final report, FDEP Contract S0108 (Link).
Further reading on buffer width, slope and phosphorus: Zhang, X., Liu, X., Zhang, M., Dahlgren, R.A. and Eitzel, M. (2010), A review of vegetated buffers and a meta-analysis of their mitigation efficacy in reducing nonpoint source pollution, Journal of Environmental Quality 39:76–84 (DOI).
Equations
Methodology. With Retention selected, BMPFast treats this BMP as retention. Retention BMPs compares how every retention BMP calculates its Treatment Depth, and Retention Methodology explains the retention curves it is read on.
With Detention + Plants, see Media and Filtration Methodology.
Retention
Treatment Depth (in) = 12 in/ft x Buffer Width x Buffer Depth x Soil Storage Capacity / (Buffer Width + Width of Area Feeding Buffer)
Hydraulic Capture (%) = retention curves (Treatment Depth, non-DCIA CN, DCIA %, rainfall zone)
N removal (%) = P removal (%) = Hydraulic Capture
Detention + Plants
N removal (%) = Nitrogen buffer table (Slope of Buffer, Buffer Width)
P removal (%) = Phosphorus buffer table (Slope of Buffer, Buffer Width)
Hydraulic Capture (%) = 0 (no volume is retained)
Example (Retention): Buffer Width 100 ft, Storage depth 0.5 ft, Soil Storage Capacity 0.4 in/in, Width of Feeder Area 10 ft gives a Treatment Depth of 12 x 100 x 0.5 x 0.4 / (100 + 10) = 2.18 in. The hydraulic capture for 2.18 in is then read from the retention curves for the catchment’s curve number, DCIA percent and rainfall zone.
Applicant’s Handbook reference
Appendix O, Green Stormwater Infrastructure: GSI “can also treat stormwater similar to a traditional BMP by treating TN and TP as a retention system”; with Retention selected BMPFast turns the buffer’s soil storage into a treatment depth and reads the Appendix O, Dry Retention Systems tables for it.
Source reference
FDEP and the water management districts (2010). Stormwater Quality Applicant’s Handbook: Design Requirements for Stormwater Treatment Systems in Florida, March 2010 draft (not adopted), Section 10.3 Calculating Load Reduction Efficiency for a Given Retention Volume (the draft, not adopted: PDF, 16 MB): a vegetated natural buffer’s load reduction is read from the dry retention tables for the volume it infiltrates; the Treatment Depth equation, soil storage over the buffer plus its feeding area, is BMPFast’s.
Results
After Calculate, the report below the inputs shows:
- Vegetated Natural Buffer Input Variables — the values you entered, including the credit choice; then Runoff Area (Width of Area Feeding Buffer × Length), Buffer Area (Width × Length), Contributing Area (their sum) and Watershed Area (the catchment’s area), in acres. A warning follows the table when the Contributing Area and the Watershed Area differ by more than 1 %.
- Watershed Characteristics — Watershed Area (acres), Contributing Area to BMP (ac), Watershed Non-DCIA Curve Number, Watershed DCIA Percent, Rainfall Zone and Rainfall (in). The Watershed Area is the area the contributing area is checked against.
- Surface Water Discharge — Provided Nitrogen and Provided Phosphorus Treatment Efficiency (%). A value of 100 % or more is shown as 99 %.
- Groundwater Discharge (Stand-Alone) — shown when Conduct Groundwater Discharge Analysis is Yes on the General Site Information: Average Annual Recharge (MG/yr, the volume infiltrated), TN and TP Mass Load (kg/yr) and TN and TP Concentration (mg/L) reaching the groundwater. With Detention + Plants nothing is retained, so these are 0.
- Surface Discharge Load Diagram — Load in (N and P in kg/yr, Q in ac-ft/yr), Treatment (N and P removal, %), Surface Discharge (N, P, Q leaving the buffer) and Mass Reduction (N and P removed, kg/yr). The diagram is for this catchment’s runoff alone, with no routing.
The strip at the bottom of the worksheet shows the project’s Maximum % Removal for TN and TP, so you can compare the provided removal with what is required.
Buttons
| Button | What it does |
|---|---|
| Calculate / Equations / Report | One button with three jobs. When you have changed an input since the last calculation it reads Calculate: it calculates with the values entered and shows the report. Once the report is current it reads Equations and shows the Equations page; it then reads Report and takes you back. Change any input and it reads Calculate again. |
| Cost | Opens the Life-Cycle Cost Analysis for this buffer (construction, replacement and maintenance costs, present worth and cost per pound of N and P removed). |
| Sizing | Opens the Sizing form, where you change the buffer’s variables (width, length, depth, feeder width, soil storage capacity, slope) with arrows and see the N and P removal against the targets on a chart. Apply keeps the new values on the buffer; Cancel discards them. Sizing works with either credit choice. See Sizing. |
| Opens the report (or the Equations page, if it is showing) in the Report Viewer, where it can be printed or saved. | |
| Help | Opens this page. |
| Back | Saves the values, calculates, and returns to the previous screen. |
The Equations page
The Equations page shows the equations for the credit choice in use, notes on how they are applied, and a Values table with the current numbers: the buffer variables, the Contributing Area, Watershed Area, Non-DCIA Curve Number, DCIA Percent, Rainfall Zone and Treatment Depth, then Hydraulic Capture (%), Treatment Rate (gpm/sf, “(no media mix)” for a buffer) and N and P removal (%). With Detention + Plants the removal rows read “N removal * with vegetation only” and “P removal * with vegetation only”, and the page adds the Nitrogen buffer table and Phosphorus buffer table, each with the value read at the current width and slope.

Notes and limits
- A buffer normally treats only the runoff from its own catchment: flows routed from upstream catchments bypass it and go on, untreated, to the next catchment, and the routing report notes it. Should one of them be designed to treat the upstream runoff too, untick Bypass upstream runoff on this catchment’s Routing screen (BMPFast asks once when a catchment is first routed into it).
- A slope over 6 % is refused: BMPFast limits the slope to 6 %: the buffer tables have data for 2 % and 6 % slopes only, and there is no data for steeper slopes. A project saved earlier with a steeper slope shows a warning in the report.
- A storage depth over 1 ft is refused the same way. Sizing starts from a depth of 2 ft, so if Sizing proposes more than 1 ft, enter 1 ft or less before you Calculate. A project saved earlier with a deeper value shows a warning in the report.
- Detention + Plants: a width outside 10 to 350 ft or a slope below 2 % gives 0 % removal.
- Retention: if the rainfall zone has not been set on the General Site Information, the capture cannot be read from the curves.
- In a Multiple BMP series, a buffer set to Retention counts as a retention BMP (its Treatment Depth is added to the other retention depths); a buffer set to Detention + Plants does not.
Example input data are shown below.

Sample problems
Worked problems solved in BMPFast, each with every input, the steps with screen captures, the program’s results, a hand check and the project file to download. Captures are for demonstration only. All of them: BMPFast sample problems.