Most BMPs in BMPFast remove nitrogen and phosphorus by retaining runoff (Retention Methodology, Retention BMPs) or by holding it in a wet pond (Wet Detention Methodology). This page covers the rest: BMPs whose removal comes from engineered media the water passes through, from the buffer tables, or from values the user enters. It explains the media mixes, the Surface Discharge Filter and its sizing, the Detention settings of the Rain Garden, Tree Well, buffer and filter strip, media in retention BMPs, the media filter service life, and User Defined BMPs.
Media mixes
A media mix is an engineered soil or filter material: sand, clay, expanded clay, tire crumb and similar materials, often called Biosorption Activated Media (BAM). Each mix carries six values. BMPFast uses the nitrogen and phosphorus reductions for removal, the void fraction for storage, the rate for sizing, and the sorption rate and saturated weight for the service life.
| Mix | TN reduction (%) | TP reduction (%) | Void fraction | Sorption rate (mg/g) | Saturated weight (lb/cf) | Treatment rate (gpm/sf) | TN / TP when residence is under 2 hours (%) |
|---|---|---|---|---|---|---|---|
| ICS | 80 | 95 | 0.30 | 0.6 | 105 | 0.104 (10.0 in/hr) | 80 / 95 |
| B&G ECT Mixes | 45 | 45 | 0.30 | 0.2 | 63 | 1.0 (96.2 in/hr) | 25 / 25 |
| SAT | 30 | 45 | 0.30 | 0.2 | 95 | 0.02 (1.9 in/hr) | 25 / 25 |
| B&G CTS12 | 60 | 90 | 0.30 | 0.2 | 95 | 0.052 (5.0 in/hr) | 60 / 90 |
| B&G CTS24 | 75 | 95 | 0.30 | 0.2 | 95 | 0.052 (5.0 in/hr) | 75 / 95 |
| Permeable Pavement | 60 | 90 | 0.30 | 0.2 | 95 | 0.052 (5.0 in/hr) | 60 / 90 |
The rate in inches per hour is the gpm/sf value × 96.25 (1 gpm over 1 sf = 96.25 in/hr). The rates include a factor of safety of 2: the B&G CTS media were tested at 10 in/hr, so BMPFast uses 5 in/hr (0.052 gpm/sf) for CTS12, CTS24 and Permeable Pavement. “Not Specified” and “None” give no media removal.
Applicant’s Handbook reference
Appendix O, Table 1 (BMP Efficiencies): media appears as “Media Mix Efficiency” (baffle boxes with a media filter) and as “additional removal based on plant, soil and media selections” (Green Stormwater Infrastructure Efforts), but the handbook gives no values for any media; the reductions, rates and void fractions here are from the UCF and FDOT research listed under Source.
Source reference
Stormwater Management Academy, UCF (n.d.). Define Media Mix Support Information (the media mix guide shipped with BMPFast, MediaMixHelp.pdf): the guide shipped with the program lists the mixes, their removals and their rates (ECT 96 in/hr, SAT 2 in/hr); BMPFast’s ECT, SAT and CTS removals and rates agree with it or with the sources below.
Ferguson Waterworks (2023). Clay Tire Sand (CTS) Media Specification, 03-03-23 (link): CTS is 85 % sand and 15 % tire crumb and clay, tested above 10 in/hr (BMPFast uses 5 in/hr, 0.052 gpm/sf, a factor of safety of 2) at a dry installation density of no more than 95 lb/cf, the value BMPFast lists as the saturated weight; the specification limits storage to an available porosity of 0.25, where BMPFast uses 0.30 (confirmed by Ron, 2026-10-16).
Ferguson Waterworks (2023). Iron Clay Sand (ICS) Media Specification, 03-01-23 (link): gives a recommended treatment rate of 5 in/hr with the factor of safety, where BMPFast uses 10 in/hr (0.104 gpm/sf) for ICS, as the FAQ on the Media Mix page says; the ICS removals of 80 % TN and 95 % TP rest on supplier “up to” figures and laboratory columns.
Environmental Conservation Solutions (2021). Bold & Gold ECT3 Biosorption Activated Media Specifications (link): gives a laboratory permeability above 96 in/hr and a design rate of 16 ft/hr with a factor of safety of 2, which is BMPFast’s 1.0 gpm/sf (96 in/hr) for B&G ECT Mixes.
Federal Highway Administration (n.d.). Stormwater Best Management Practices in an Ultra-Urban Setting, fact sheet Surface Sand Filters (City of Austin 1990 data) (link): Austin surface sand filters removed 27 % to 71 % TN and 27 % to 80 % TP, with a sand permeability of about 1.75 in/hr; BMPFast’s SAT (30 % TN, 45 % TP, 0.02 gpm/sf) lies within these.
- Residence time under 2 hours. The Media Mix window asks whether the media design residence time is more than 2 hours. When the answer is No, B&G ECT Mixes and SAT give 25 % TN and 25 % TP instead of their full values; the other mixes are unchanged. The Surface Discharge Filter’s Sizing window treats a filter fed by a wet detention pond as under 2 hours. The same rule applies to every BMP that uses media.
- Your own mixes. Choosing “User Defined” in any media list opens the media mix library. There you add, edit, rename and delete your own named mixes with the same six values. They are saved on your computer (%AppData%\BMPFast\MediaMix.json) and listed after the built-in mixes. A project that uses your mix stores its six values, so it opens on another computer with the same results.
- More on each mix, its materials and where it is used: Media Mix.
Source reference
Wanielista, M. and Flint, M. (2014). Up-flow Filtration for Wet Detention Ponds. Florida Stormwater Association Annual Meeting, June 12, 2014: an ECT3 filter removes 45 % on its own but 25 % after a wet detention pond, because the pond has already removed the particulate part; BMPFast uses 25 % for B&G ECT Mixes when the residence time is 2 hours or less.
Ferguson Enterprises (2022). Bold & Gold Biosorption Activated Media (BAM) for Enhanced Pollutant Removal in Florida (brochure) (link): a filter downstream of a wet pond removes “25% of the nitrogen and phosphorus”.
BMPFast method (MediaMix.cs): applying the same 25 % to SAT, and treating a filter fed by a wet pond as under 2 hours (Ron, 2026-10-01), are BMPFast’s own rules.
Surface Discharge Filter
A Surface Discharge Filter passes runoff through media and discharges the filtered water to the surface. It retains nothing, so its removal is not its capture: it is the share of the runoff it treats times the media’s reduction. It is often placed after a retention basin or a wet pond, and treats what they let through. The worksheet is described on Surface Discharge Filter.
Capture (%) = retention curves (Treatment Depth, Non-DCIA CN, DCIA %, zone)
Filter N removal (%) = Capture × Media N reduction / 100
Filter P removal (%) = Capture × Media P reduction / 100
With no media (None or Not Specified) the filter removes nothing.
The capture is read from the same retention curves (Retention Methodology). The Treatment Depth (0 to 4 in) is entered on the worksheet, or found by the filter’s Sizing window from the filter’s surface area. The Recovery-Time Adjustment does not apply to a filter.
Applicant’s Handbook reference
Section 2.0 Definitions and Terms, “Detention with filtration”: the removal of pollutants by temporary storage and gradual release “through an appropriately-sized engineered media or filter system”.
Appendix O, Detention with Engineered Media and Filtration: “Treatment efficiency for Detention Pond with Filtration = (Detention efficiency for Volume of the water Detained in the system) + (Volume of water filtered and not detained * Treatment Efficiency of Media)”; a Surface Discharge Filter detains nothing, so BMPFast keeps the second term: the share of runoff the filter treats times the media’s reduction.
Source reference
BMPFast method (Filtration.cs): a Surface Discharge Filter’s capture is read from the dry retention tables at its Treatment Depth and multiplied by the media’s reduction; the tables come from Harper and Baker (2007), but using them for the share of runoff a filter passes is BMPFast’s own step.
Sizing the filter by its surface area
The filter’s Sizing window works from the surface area of media you build. The water it must treat is what the upstream BMP discharges: a retention basin passes on (100 − its Hydraulic Capture) % of the runoff, a wet pond passes on all of it, and with no upstream BMP the filter takes the whole catchment’s runoff.
Area Discharging to Filter (ac) = Catchment Area (ac) × (100 − Upstream Hydraulic Capture (%)) / 100
Treatment Depth (in) = Filter Area (sf) × Rate (gpm/sf) / (18.85 × Area Discharging to Filter (ac))
Minimum Filter Area (sf) = Area Discharging to Filter (ac) × Treatment Depth (in) × 18.85 / Rate (gpm/sf)
Total N removal (%) = Upstream N + Filter N × (100 − Upstream N) / 100 (P the same)
Where 18.85 comes from. One gpm is 0.0022288 cfs, so one day at 1 gpm is 0.0022288 × 86,400 = 192.57 cf. One inch of runoff over one acre is 43,560 / 12 = 3,630 cf. So 18.85 = 3,630 / 192.57: the Treatment Depth is the depth of runoff, over the area discharging to the filter, that the media can pass in one day at its rate. The rate includes the media’s safety factor. The area found is the minimum: a larger filter is acceptable, and the removal assumes at least this area is built. There is no calculation for an undersized filter.
Source reference
BMPFast method (Surface Discharge Filter Sizing, frmFilterSizing; upstream wet pond treated as under 2 hours, Ron, 2026-10-01): 18.85 is a unit conversion (one inch over one acre, 3,630 cf, divided by one day at 1 gpm, 192.57 cf); the area found is the minimum for that Treatment Depth, and there is no credit for an undersized filter.
The total is an ordinary treatment train: the filter acts only on what the upstream BMP passes on.
Applicant’s Handbook reference
Section 9.5.1 Treatment Train Nutrient Reduction (Equation 9-5): BMPs in series are combined as 1 − [(1 − Eff1) × (1 − Eff2)]; BMPFast’s Total removal is this, and it is also the Appendix O detention-with-filtration equation with the upstream BMP as the detention part.
Worked example: a filter after a retention basin
Example Problem 3: an 11 ac catchment in Zone 4, Non-DCIA CN 65, DCIA 25 %, with a retention basin of 0.552 in Treatment Depth that captures 75.01 % of the runoff. A Surface Discharge Filter of B&G CTS12 media (60 % TN, 90 % TP, 0.052 gpm/sf) follows it.
| Step | Filter of 500 sf | Filter of 1,000 sf |
|---|---|---|
| Area Discharging to Filter | 11 × (100 − 75.01) / 100 = 2.749 ac | 2.749 ac |
| Treatment Depth | 500 × 0.052 / (18.85 × 2.749) = 0.502 in | 1.003 in |
| Filter capture (retention curves) | 73.36 % | 86.14 % |
| Filter N / P removal | 73.36 × 0.60 = 44.01 % / 73.36 × 0.90 = 66.02 % | 51.69 % / 77.53 % |
| Total N | 75.01 + 44.01 × (100 − 75.01) / 100 = 86.01 % | 87.92 % |
| Total P | 75.01 + 66.02 × (100 − 75.01) / 100 = 91.51 % | 94.38 % |
BMPFast’s sizing engine gives the same values (86.0064 % and 91.5068 % at 500 sf). Doubling the filter adds about 2 points of N: most of the treatment is already done by the basin.
Other methods: this example’s method compared with adding the Treatment Depths, with a plot: Comparison of Methods for Calculating Retention Followed by a Surface Discharge Filter.
Media under a retention BMP
A retention BMP (Retention, Exfiltration, Permeable Pavement, Rain Garden set to Retention, and others) can also name a media mix. The media does not change its surface removal, which is its capture. It treats the water that soaks into the ground, and so lowers what reaches the groundwater:
Groundwater N load in (kg/yr) = N load in × Capture (%) / 100
Groundwater N load out (kg/yr) = Groundwater N load in × (100 − Media N reduction) / 100
Groundwater TN (mg/L) = TN EMC × (100 − Media N reduction) / 100 (P the same)
These appear in the report’s Groundwater Discharge table.
Applicant’s Handbook reference
Section 8.5.2 Additional Permitting Requirements to Protect Ground Water: stormwater treatment systems must be designed so they do not “result in a violation of ground water standards, outside an applicable Zone of Discharge”; BMPFast’s Groundwater Discharge table gives the load and concentration reaching the groundwater, but it does not check them against those standards.
Detention settings of other BMPs
Several BMPs can be set to treat runoff and discharge it, rather than retain it. Each then uses its own rule:
| BMP and setting | Removal | Capture |
|---|---|---|
| Rain Garden, Detention | N (%) = Credit + (100 − Credit) × Media N reduction / 100 (P the same). The Credit for Native Soil and Cover Crop applies first, then the media treats what is left. With no media, the removal is the credit alone. | 0 (nothing is retained) |
| Tree Well, Detention | N (%) = Capture × Media N reduction / 100 (P the same), like a Surface Discharge Filter. | From the retention curves, at the well’s Treatment Depth |
| Vegetated Natural Buffer, Detention + Plants; Vegetated Filter Strip, Detention | N and P from the buffer tables, by buffer width and slope (2 to 6 %). The source of the tables is on the Vegetated Buffer page. | 0 |
Applicant’s Handbook reference
Appendix O, Table 1 (BMP Efficiencies), Green Stormwater Infrastructure Efforts: for rain gardens, tree wells, vegetated natural buffers and vegetated filter strips, “Use appropriate retention or detention calculation for volume captured then add an additional removal based on plant, soil and media selections in a treatment train configuration”; the Rain Garden and Tree Well detention rules follow this. The buffer tables are not from the handbook.
Media filter service life
Media removes phosphorus partly by sorption, and its sorption capacity is used up over time. The Media Filter Service Life calculator (Media Filter Service Life) estimates how long a filter lasts:
Total P (kg/yr) = P removed by the BMP − P removed upstream + P from sources other than runoff
OP removed (mg/yr) = 1,000,000 × Total P × Fraction that is ortho-phosphate
OP capacity (mg) = Filter Volume (cf) × Saturated Weight (lb/cf) × 454 g/lb × Sorption Rate (mg/g)
Service Life (yr) = OP capacity / OP removed
Volume for 30 years (cf) = 30 × OP removed / (454 × Saturated Weight × Sorption Rate)
For example, 100 cf of B&G CTS12 (95 lb/cf, 0.2 mg/g) holds 100 × 95 × 454 × 0.2 = 862,600 mg of ortho-phosphate. If the filter removes 1 kg/yr of P of which 40 % is ortho-phosphate (400,000 mg/yr), it lasts about 2.2 years, and 30 years would need about 1,390 cf. (These numbers illustrate the equations; they are not from a project.) For a Rain Garden the P removed is the P it retains and the filter volume is its media volume; for a Surface Discharge Filter it is the P load in × its P removal.
Source reference
BMPFast method (frmMediaFilterServiceLife): the service life method is BMPFast’s; the sorption rates and weights come from the media sources.
Chang, N.-B. et al. (2018). Bio-sorption Activated Media for Nitrogen Removal in a Rapid Infiltration Basin, Monitoring Project. Final report, FDEP Project Agreement NS 003, City of DeLand and UCF (link): the CTS media had a dissolved phosphorus removal capacity above 0.2 mg per gram, BMPFast’s sorption rate for the CTS mixes and Permeable Pavement.
Ferguson Waterworks (accessed 2026-10-16). Bold & Gold Filtration Media (product page) (link): one pound of the media holds 91 mg of dissolved phosphorus, which is 0.20 mg/g; no opened source gives ICS’s 0.6 mg/g or SAT’s 0.2 mg/g.
User Defined BMPs
A User Defined BMP is any treatment BMPFast has no equation for: baffle boxes, hydrodynamic separators, catch basin inserts, alum treatment, street sweeping or other. You enter its nitrogen and phosphorus removal (%) directly, from a source the reviewing agency accepts. BMPFast applies them to the annual load that reaches the BMP, as one step of the treatment train, and calculates nothing else for it: no capture, no volume removed, no sizing. See User Defined.
Applicant’s Handbook reference
Section 9.5.2 Alternative Designs: BMPs not in Volume II or Appendix O are alternative designs, and the applicant must give reasonable assurance, with test data, of the treatment claimed; a User Defined BMP needs that support.
Appendix O, Table 1 (BMP Efficiencies): gives fixed values for some of these BMPs (baffle boxes, first generation 2.30 % TP and 0.50 % TN; second generation 15.50 % TP and 19.05 % TN; hydrodynamic separators 10 % TP) and methods for others (catch basin inserts, alum injection); BMPFast does not fill them in, so enter them yourself.
Source
- The media mixes and their reductions come from UCF Stormwater Management Academy and FDOT research, as listed in BMPFast’s media mix guide: Wanielista et al., Demonstration Bio Media for Ultra-urban Stormwater Treatment, FDOT BDK78 977-19 (2014); Ryan et al., Nutrient Reduction in a Stormwater Pond Discharge in Florida, Water Air Soil Pollution (2010); Wanielista and Flint, Up-Flow Filtration for Wet Detention Ponds, Florida Stormwater Association (2014); City of Austin Environmental Criteria Manual, Section 1.6.5 (2012) for SAT; Wanielista et al., Nitrogen Transport and Transformation in Retention Basins, Marion County, FDEP (2011); Williams and Wanielista, Improving Nitrogen Efficiencies in Dry Ponds, Florida Stormwater Association (2015).
- Biosorption Activated Media: Chang, N.-B., Wen, D., Colona, W. and Wanielista, M.P. (2019), Comparison of biological nutrient removal via two biosorption-activated media between laboratory-scale and field-scale linear ditch for stormwater and groundwater co-treatment, Water, Air, & Soil Pollution 230:151 (DOI); Wanielista and Chang (2008), Alternative Stormwater Sorption Media for the Control of Nutrients, for the SWFWMD (Link).
- The BMP Trains model: BMP Trains 2020 User Manual, Stormwater Management Academy, University of Central Florida (Link), sections 13 (Filter Systems) and 14 (Biofiltration Systems with Biosorption Activated Media).
Sample problems
Worked problems solved in BMPFast, each with every input, the steps with screen captures, the program’s results, a hand check and the project file to download. Captures are for demonstration only. All of them: BMPFast sample problems.
- Surface discharge filter with B&G CTS12
- Surface discharge filter with B&G CTS24 for an impaired water
- Retention rain garden in a parking island
- Detention rain garden with an underdrain
- Tree wells along a street (retention)
- Tree wells with an underdrain and media (detention)
- Vegetated natural buffer behind homes (retention)
- Vegetated natural buffer with plants (detention)
- Vegetated filter strip beside a parking lot (retention)
- Vegetated filter strip with media (detention)
- Sizing a filter after a retention basin
- Sizing a filter after a wet pond
- Service life of a B&G CTS24 filter
- Filter area for a 20-year service life
- Media mix: a filter with and without media
- Media mix: residence time under and over 2 hours